Application:
- evaporation of small to medium-sized quantities of gas at moderate to low pressures (types SR, NDA, HDA),
- post-heating after atmospheric evaporators (types NDA, HDA)
- evaporation / preheating where connection to hot water or fuel supplies is not possible
Design features:
- compact design
- minimum erosion, as there is no direct contact between the medium and the heating elements
- heating element easily replaceable, thus upgrading to higher heating power possible in most cases
- standard design with dual-step control
- exact temperature control via thyristor controller
- space-saving horizontal or vertical design
Technical Data
| media | N2, O2, Ar, CO2, He, CH4, LNG |
| inlet temperature | -196°C to -20°C |
| outlet temperature | 0 to +60°C ±15°C (±1°C with thyristor control) |
| max. operating pressure | 100 bar (CENTREX SR); 420 bar (HDA) |
| throughput | 1 to 3000 Nm3/h |
| heating power | 0.5 to 80 kW |
| control | temperature recording via a resistance probe in the outlet; dual-step controller or microprocessor controlled P, PI or PID control using thyristor technology |
| overheat protection | via electronic temperature switch |
| heating element | ceramic heater |
| power supply | 230 / 400 V - 50 Hz (standard) |
| connections | flanges in accordance with DIN / ASA |
| materials | 1.4541, 1.4571 (HDA / NDA additionally: copper, aluminium) |
|